On possibility of determining to the Curie constant and magnetic susceptibility for colloidal solutions by nuclear magnetic resonance method
The new universal methodic of the Curie constant C and magnetic susceptibility determination with an accuracy of no more than 1.0 % for colloidal solutions, which are located in hermetic volume (for example, ferrofluidic cell) is suggested. The experimental investigations were showed that the Curie's law is performing for temperature T variation range from 283 to 323 K, which corresponds to the application of ferrofluidic cells. It was found that the temperature T increase in ferrofluidic cell of colloidal solution with 324 to 363 K is leading a slight increase C . It's necessary to take account at carrying of experiments with using of the data cell. The results of colloidal solutions investigations are presented.
Keywords
ядерный магнитный резонанс, магнитное поле, магнитная восприимчивость, константа Кюри, коллоидный раствор, температура, линия нутации, nuclear magnetic resonance, magnetic field, magnetic susceptibility, Curie constant, colloidal solution, temperature, nutation lineAuthors
Name | Organization | |
Davydov V.V. | Peter the Great Saint-Petersburg Polytechnical University; The Bonch-Bruevich Saint-Petersburg State University of Telecommunications; All Russian Research Institute of Phytopathology | davydov_vadim66@mail.ru |
Myazin N.S. | Peter the Great Saint-Petersburg Polytechnical University | myazin.n@list.ru |